Essential
Power Selector |
Operating
Gen
|
F/E
|
|
Thrust
Lever |
Close
|
C
|
|
Start
Lever |
Cutoff
|
C
|
|
Engine
Fire Switch |
Pull
|
C
|
|
|
|
|
|
If
fire warning light remains illuminated |
|
|
|
Bottle
Discharge Switch
|
Push
|
C
|
|
Bottle
Discharge Light |
On |
C
|
|
Bottle
Transfer Switch |
Transfer |
C
|
|
|
|
|
|
If
after 30 seconds the fire warning light remains illuminated
|
|
|
|
Bottle
Discharge Switch
|
Push |
C
|
|
Bottle
Discharge Light |
On |
C
|
|
If
fire warning light remains illuminated
|
|
|
|
Land
at nearest suitable airport
|
|
|
|
|
|
|
|
Galley
Power Switch |
Off |
F/E
|
|
Cargo
Heat Outflow Switch (if applicable) |
Close |
F/E
|
|
If
flaps extented |
|
|
|
Pack
Switch |
Off |
F/E
|
|
Cargo
Heat Outflow Switch |
Close |
F/E
|
|
|
|
|
|
Generator
Field |
Tripped |
F/E
|
|
Electrical
Load |
Monitor |
F/E
|
|
Fuel
Shutoff Switch |
Close |
F/E
|
|
Hydraulic
System A Fluid Shutoff Swtch |
Close |
F/E
|
|
Engine
Bleed Air Switch |
Close |
F/E
|
|
Pack
Switch (if applicable) |
Off |
F/E
|
|
Wing
& Engine Inlet Anti-Ice Switches (affected engine) |
Close |
F/O
|
|
*
Accomplish the one/two generator inoperative, auto pack trip
(if required), and one/to engine(s) inoperative landing checklists
|
|
|